Overview
The GMS800 FIDOR extractive gas analyzer of the GMS800 analyzer family is ideally suited for emission measurements according to regulatory requirements (in waste incineration plants, cement and/or power plants, for example). Based on the proven flame ionization detection principle, the GMS800 FIDOR measures total hydrocarbon concentrations in gases at both trace levels and high concentration levels. The GMS800 FIDOR is available in three types: the GMS810 FIDOR with integrated BCU control unit, the GMS811 FIDOR with separate BCU control unit, and the GMS840 FIDOR in a space-saving wall housing. The housing makes stand-alone operation and integration into existing systems such as the MCS200HW multi-component analyzer from SICK very easy.
At a glance
- Standard 19” enclosure for easy integration into all industry-typical systems
- Space-saving wall housing (stand-alone)
- Nearly maintenance free ejector pump delivers sample gas to the analyzer
- Integrated catalytic converter (option) provides very clean zero gas
- Automatic regulation and compensation of process pressure fluctuations
- Protective filter at sample gas inlet
- High degree of linearity (≤ 2 %) for very low and high measuring ranges