Extractive gas analyzers
GMS800
Your Benefits
- Suitability tested according to EN 15267 and EN 14181
- Installation in non-explosion-hazardous areas and explosion-hazardous areas (Zones 1 and 2 according to ATEX) possible
- Modular design for minimum service and maintenance as well as easy upgrading of existing installations
- Adjustment possible without test gases via optional adjustment unit
- Influence of ambient temperature very minimal thanks to thermostatic measurement modules
- Proven measurement technology for reliable measurement
- Replaceable assemblies and modules for easy maintenance and repair





Overview
The GMS800 is a product family of extractive gas analyzers which can measure more than 60 different gas components. The GMS800 is characterized by its modular design: 6 analyzing modules, one gas module, I/O modules and a control unit. Standardized 19” plug-in housings can be used for economical system integration. In harsh industrial environments, wall-mounted housings with approvals for Ex-zones according to ATEX are used. Equipped with user-friendly software, the GMS800 features all the interfaces required for remote control via networks through to the connection to a distributed control system.
- 6 different analyzer modules: DEFOR (NDUV, UVRAS), MULTOR (NDIR), OXOR-E (electrochemical O2), OXOR-P (paramagnetic O2), THERMOR (TC), and UNOR (NDIR)
- 4 different types of enclosures
- Gas module with sample gas pump and/or control sensors
- New enclosure type for easy and quick integration in analyzer systems
- Remote diagnosis via Ethernet with SOPAS ET software
Spare parts
Applications
Service & Support
Technical overview
- GMS800 system
GMS800 system
Measured values Ar, CH4, CH3OH, C2H2, C2H2F4, C2H4, C3H6, C3H8, C4H6, Cl2, CO, CO2, COCl2, COS, CS2, H2, H2S, He, NH3, NO, N2O, NO2, O2, SF6, SO2, other components on request Performance-tested measurands CH4, CO, CO2, NO, NO2, O2, SO2 Gas flow rate 30 l/h ... 60 l/h Sample gas temperature Analyzer inlet 0 °C ... +45 °C Process pressure Hosed gas lines –200 hPa ... 300 hPa Tubed gas lines –200 hPa ... 1,000 hPa Process gas humidity Non-condensing Dust load Free of dust and aerosols Ambient temperature +5 °C ... +45 °C Storage temperature –20 °C ... +70 °C Ambient pressure 700 hPa ... 1,200 hPa Geographical altitude + 2,500 m (above mean sea level) Ambient humidity 20 % ... 90 %
Relative humidity; non-condensingElectrical safety CE
- GMS810 design
GMS810 design
Description 19″ rack enclosure with 4 rack units, for integration in cabinets Electrical safety CE Enclosure rating IP40 Dimensions (W x H x D) 483 mm x 178 mm x 388 mm (for details see dimensional drawings) Weight 9 kg ... 20 kg
Depending on configurationPower supply Voltage 93 V AC ... 132 V AC 210 V AC ... 370 V AC 186 V AC ... 264 V AC Frequency 47 ... 63 Hz Power consumption ≤ 300 VA Sample gas connections PVDF bulkhead fitting: for hose 6 x 1 mm Auxiliary gas connections For purge gas or flowing reference gas: option Options Gas connections: Swagelok 6 mm or Swagelok 1/4″
- GMS811 design
GMS811 design
Description 19″ rack enclosure with 4 rack units, for usage with separate control unit (BCU), for integration in cabinets Electrical safety CE Enclosure rating IP40 Dimensions (W x H x D) 483 mm x 178 mm x 388 mm (for details see dimensional drawings) Weight 9 kg ... 20 kg
Depending on configurationPower supply Voltage 93 V AC ... 132 V AC 210 V AC ... 370 V AC 186 V AC ... 264 V AC Frequency 47 ... 63 Hz Power consumption ≤ 300 VA Sample gas connections PVDF bulkhead fitting: for hose 6 x 1 mm Auxiliary gas connections For purge gas or flowing reference gas: option Options Gas connections: Swagelok 6 mm or Swagelok 1/4″
- GMS820P design
GMS820P design
Description Flame-proof enclosure for use in Ex-zone 1 areas Ex-approvals IECEx Ex db eb [ia] IIC T6 ATEX II 2G Ex db eb [ia] IIC T6 Gb II 2G Ex db eb IIC T6 Gb Electrical safety CE Enclosure rating IP65 Dimensions (W x H x D) 790 mm x 590 mm x 353 mm (for details see dimensional drawings) Weight 140 kg ... 150 kg
Depending on configurationPower supply Voltage 93 V AC ... 132 V AC 210 V AC ... 370 V AC 186 V AC ... 264 V AC Frequency 47 ... 63 Hz Power consumption ≤ 300 VA Sample gas connections Inside thread G1/4″ Auxiliary gas connections For purge gas or flowing reference gas: option Options Gas connections: Swagelok 6 mm or Swagelok 1/4″
- GMS840 design
GMS840 design
Description Closed sheet steel housing for wall mounting for use indoors Ambient temperature +5 °C ... +45 °C Storage temperature –10 °C ... +70 °C Ambient humidity 10 % ... 95 %
Non-condensingEx-approvals IECEx GMS841: Ex nA nC IIC T4 Gc GMS841: Ex nA nC [ia Ga] IIC T4 Gc ATEX GMS841: II 3G Ex nA nC IIC T4 Gc GMS841: II 3G Ex nA nC [ia Ga] IIC T4 Gc NEC/CEC (US/CA) GMS842: Class I, Division 2, Groups A, B, C and D; T4 GMS842: Ex nA nC IIC T4 Gc GMS842: Ex nA nC [ia Ga] IIC T4 Gc GMS842: Class I, Zone 2 AEx nA nC IIC T4 Gc GMS842: Class I, Zone 2 AEx nA nC [ia Ga] IIC T4 Gc Electrical safety CE Enclosure rating IP66 / NEMA 4x Dimensions (W x H x D) 522 mm x 475 mm x 478 mm (for details see dimensional drawings) Weight 30 kg
Depending on configurationPower supply Voltage 85 V AC ... 264 V AC Frequency 47 ... 63 Hz Current consumption ≤ 10 A Power consumption ≤ 300 VA
Depending on configurationSample gas connections Inside thread G1/4″: for screw-in fittings Swagelok 6 mm: stainless steel, for metal tube Swagelok 1/4″: stainless steel, for metal tube PVDF compression fitting: for hose 6 x 1 mm
- DEFOR analyzer module
DEFOR analyzer module
Description UV gas analyzer for simultaneous measurement of up to 3 gas components Measurement principles NDUV spectroscopy, UVRA spectroscopy Measuring ranges Cl2 0 ... 125 ppm / 0 ... 100 Vol.-% COS 0 ... 250 ppm / 0 ... 100 Vol.-% CS2 0 ... 50 ppm / 0 ... 30 Vol.-% H2S 0 ... 25 ppm / 0 ... 100 Vol.-% NH3 0 ... 50 ppm / 0 ... 100 Vol.-% NO 0 ... 10 ppm / 0 ... 100 Vol.-% NO2 0 ... 50 ppm / 0 ... 100 Vol.-% NO2(*) 0 ... 10 ppm / 0 ... 100 Vol.-% SO2 0 ... 25 ppm / 0 ... 100 Vol.-% SO2(*) 0 ... 10 ppm / 0 ... 100 Vol.-% (*) NO2, SO2: Smallest measuring range with daily adjustment of zero point and operation in an air-conditioned environment with temperature stability of ± 2 °C Certified measuring ranges NO 0 ... 50 mg/m³ / 0 ... 1,000 mg/m³ / 0 ... 2,000 mg/m³ NO2 0 ... 50 mg/m³ / 0 ... 500 mg/m³ SO2 0 ... 75 mg/m³ / 0 ... 287 mg/m³ / 0 ... 2,000 mg/m³ Response time (t90) 4 s
Typical at 60 l/h, depending on cell length and gas flowSensitivity drift ≤ 1 %: of measuring range full scale per week Zero point drift ≤ 1 %: of measuring range full scale per week Measuring ranges smaller than 2 x smallest measuring range ≤ 2 %: of measuring range full scale per week NO, NO2, SO2 ≤ 1 %: of smallest measuring range per day Conformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS
Corrective functions Manual or automatic adjustment with test gases or adjustment cell Test functions Self test and fault diagnosis
- MULTOR analyzer module
MULTOR analyzer module
Description Multi-component NDIR analyzer for continuous measurement of up to 3 IR-absorbing gases and H2O for internal interference sensitivity correction Measurement principles NDIR spectroscopy Measuring ranges CH4 0 ... 400 ppm / 0 ... 100 Vol.-% CO 0 ... 160 ppm / 0 ... 100 Vol.-% CO2 0 ... 100 ppm / 0 ... 100 Vol.-% NO 0 ... 190 ppm / 0 ... 100 Vol.-% SO2 0 ... 90 ppm / 0 ... 100 Vol.-% Certified measuring ranges CH4 0 ... 286 mg/m³ / 0 ... 500 mg/m³ CO 0 ... 200 mg/m³ / 0 ... 2,000 mg/m³ CO2 0 ... 25 Vol.-% NO 0 ... 250 mg/m³ / 0 ... 2,500 mg/m³ SO2 0 ... 250 mg/m³ / 0 ... 2,000 mg/m³ Response time (t90) ≤ 25 s
At 60 l/h, depending on cuvette length, gas flow and number of measuring componentsSensitivity drift ≤ 1 %: of measuring range full scale per week Zero point drift ≤ 1 %: of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range ≤ 2 %: of smallest measuring range per week Conformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS
Corrective functions Manual or automatic adjustment with test gases or adjustment cell Test functions Self test and fault diagnosis
- OXOR-E analyzer module
OXOR-E analyzer module
Description Determination of oxygen content using an electrochemical cell Measurement principles Electrochemical cell Measuring ranges O2 0 ... 10 Vol.-% / 0 ... 25 Vol.-% Certified measuring ranges O2 0 ... 25 Vol.-% Response time (t90) 20 s
Typical at 60 l/h, depending on gas flowSensitivity drift ≤ 2 %: of measuring range full scale per week Zero point drift ≤ 2 %: of smallest measuring range per month Process pressure Analyzer inlet –200 hPa ... 300 hPa
RelativeConformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS
Corrective functions Manual or automated adjustment with test gases Test functions Self test and fault diagnosis
- OXOR-P analyzer module
OXOR-P analyzer module
Description Accurate oxygen analyzer which operates according to the paramagnetic measurement principle Measurement principles Paramagnetic dumbbell principle Measuring ranges O2 0 ... 3 Vol.-% / 0 ... 100 Vol.-% Optional: smallest measuring range 0 ... 1 vol% Certified measuring ranges O2 0 ... 25 Vol.-% Response time (t90) ≤ 4 s
At a gas flow of 60 l/hSensitivity drift ≤ 1 %: of measuring range full scale per week Zero point drift ≤ 1 %: of smallest measuring range per week Measuring ranges smaller 5 vol% ≤ 0.05 Vol.-%: per week Conformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS
Corrective functions Manual or automated adjustment with test gases Test functions Self test and fault diagnosis Remark Special versions with highly solvent-resistant or highly corrosion-resistant measuring cells available
- THERMOR analyzer module
THERMOR analyzer module
Description Heat conductivity analyzer for the determination of concentrations in binary or quasi-binary gas mixtures Measurement principles Thermal conductivity measurement Measuring ranges Ar in N2 0 ... 10 Vol.-% / 0 ... 100 Vol.-% Ar in O2 0 ... 10 Vol.-% / 0 ... 100 Vol.-% CH4 in biogas 0 ... 60 Vol.-% / 0 ... 100 Vol.-% CO2 in air 0 ... 10 Vol.-% / 0 ... 100 Vol.-% H2 in Ar 0 ... 1 Vol.-% / 0 ... 100 Vol.-% H2 in CH4 0 ... 1 Vol.-% / 0 ... 100 Vol.-% H2 in CO2 0 ... 1 Vol.-% / 0 ... 100 Vol.-% H2 in blast furnace gas 0 ... 1 Vol.-% / 0 ... 100 Vol.-% H2 in N2 0 ... 1 Vol.-% / 0 ... 100 Vol.-% He in N2 0 ... 2 Vol.-% / 0 ... 100 Vol.-% NH3 in CO2 0 ... 15 Vol.-% / 0 ... 100 Vol.-% NH3 in air 0 ... 15 Vol.-% / 0 ... 100 Vol.-% Response time (t90) ≤ 20 s
At a gas flow of 60 l/hSensitivity drift ≤ 1 %: of measuring range full scale per week Zero point drift ≤ 1 %: of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range ≤ 2 %: of smallest measuring range per week Corrective functions Manual or automated adjustment with test gases Test functions Self test and fault diagnosis
- UNOR analyzer module
UNOR analyzer module
Description Highly selective NDIR analyzer for continuous measurement of almost any gas component which absorbs in the infra-red spectral range Measurement principles NDIR spectroscopy Measuring ranges C2H2 0 ... 300 ppm / 0 ... 100 Vol.-% N2O 0 ... 25 ppm / 0 ... 100 Vol.-% NO 0 ... 75 ppm / 0 ... 100 Vol.-% NH3 0 ... 300 ppm / 0 ... 100 Vol.-% C2H2F4 0 ... 100 ppm / 0 ... 100 Vol.-% C2H4 0 ... 300 ppm / 0 ... 100 Vol.-% C3H6 0 ... 300 ppm / 0 ... 100 Vol.-% C3H8 0 ... 100 ppm / 0 ... 100 Vol.-% C4H6 0 ... 5,000 ppm / 0 ... 20 Vol.-% CH4 0 ... 70 ppm / 0 ... 100 Vol.-% CH3OH 0 ... 150 ppm / 0 ... 10 Vol.-% CO 0 ... 20 ppm / 0 ... 100 Vol.-% CO+CO2 0 ... 50 ppm / 0 ... 100 Vol.-% CO2 0 ... 10 ppm / 0 ... 100 Vol.-% COCl2 0 ... 200 ppm / 0 ... 10 Vol.-% SF6 0 ... 50 ppm / 0 ... 100 Vol.-% SO2 0 ... 26 ppm / 0 ... 100 Vol.-% More than 60 measuring components available Certified measuring ranges CO 0 ... 75 mg/m³ / 0 ... 750 mg/m³ / 0 ... 3,000 mg/m³ CO2 0 ... 25 Vol.-% N2O 0 ... 50 mg/m³ / 0 ... 500 mg/m³ NO 0 ... 100 mg/m³ / 0 ... 1,000 mg/m³ / 0 ... 2,000 mg/m³ SO2 0 ... 75 mg/m³ / 0 ... 287 mg/m³ / 0 ... 2,000 mg/m³ NOx 0 ... 100 mg/m³ / 0 ... 1,000 mg/m³ / 0 ... 2,000 mg/m³ CH4 0 ... 50 mg/m³ / 0 ... 500 mg/m³ Response time (t90) 3 s
Typical at 60 l/h, depending on cell length and gas flowSensitivity drift ≤ 1 %: of measuring range full scale per week Zero point drift ≤ 1 %: of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range ≤ 2 %: of smallest measuring range per week Conformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS
Corrective functions Manual or automatic adjustment with test gases or adjustment cell Test functions Self test and fault diagnosis
- BCU control unit
BCU control unit
Modbus ✔ , ✔ Type of fieldbus integration TCP RTU RS-485 Ethernet ✔ Function Connection to SOPAS ET software or OPC server Indication Status LEDs: “Power,” “Failure,” and “Maintenance request” LC display Operation Via LC display and membrane keyboard
- I/O module
I/O module
Description Closed module with top-hat rail adapter or module for integration into enclosures Analog outputs 4 outputs:
0/2/4 ... 20 mA, 500 Ω
Electrically isolatedAnalog inputs 2 inputs:
0/4 ... 20 mA
Not electrically isolatedDigital outputs 8 outputs:
34 V AC, 500 mA / 48 V DC, 500 mADigital inputs 8 inputs:
42 V
All inlets with common reference potential
- Gas module
Gas module
Sample gas connections PVDF compression fitting: for hose 6 x 1 mm Swagelok 6 mm: stainless steel, for metal tube Swagelok 1/4″: stainless steel, for metal tube Options Magnetic piston pump (0 ... 60 l/h at 100 hPa low pressure)
Humidity sensor
Pressure sensor (500 ... 1500 hPa)
Flow sensor (0 ... 100 l/h, ±20%)